{"product_id":"flir-si2-pro-no-wi-fi-acoustic-imaging-camera-for-partial-discharge-pressurized-leak-and-mechanical-fault-detection-no-wifi","title":"Flir Si2-Pro-No-Wi-Fi - Acoustic Imaging Camera for Partial Discharge, Pressurized Leak, and Mechanical Fault Detection (No WiFi)","description":"\u003ch3\u003eFLIR Si2-Pro-No-Wi-Fi Acoustic Imaging Camera for Partial Discharge, Pressurized Leak \u0026amp; Mechanical Fault Detection\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLIR Si2-Pro-No-Wi-Fi\u003c\/strong\u003e is a professional \u003cstrong\u003eacoustic imaging camera designed for partial discharge, pressurized leak, and mechanical fault detection\u003c\/strong\u003e. This no-Wi-Fi version provides comprehensive acoustic inspection capabilities for industrial facilities where wireless connectivity is not required or permitted.\u003c\/p\u003e\n\u003cp\u003eThe camera helps maintenance teams identify \u003cstrong\u003ebearing problems and other mechanical faults\u003c\/strong\u003e at an early stage, helping prevent costly repairs and unexpected downtime. It can also \u003cstrong\u003equantify the leak rate and associated cost of industrial gas and compressed air leaks\u003c\/strong\u003e, allowing users to prioritize repairs and calculate potential savings.\u003c\/p\u003e\n\u003cp\u003eFor electrical equipment, the Si2-Pro-No-Wi-Fi provides \u003cstrong\u003eon-camera and software-based severity assessment and type classification of partial discharge (PD) issues\u003c\/strong\u003e, supporting informed maintenance decisions and response planning.\u003c\/p\u003e\n\u003cp\u003eThe camera is designed for efficient field inspections with \u003cstrong\u003eautomatic frequency tuning, 8x digital zoom, a 12 MP digital camera, IP54 protection, and an integrated QR code reader\u003c\/strong\u003e. It also supports fleet management and enterprise data integration for large-scale industrial maintenance programs.\u003c\/p\u003e\n\u003cp\u003eFor specialized applications, the \u003cstrong\u003eFLIR Si2-LD-No-Wi-Fi\u003c\/strong\u003e focuses on leak and mechanical fault detection, while the \u003cstrong\u003eFLIR Si2-PD-No-Wi-Fi\u003c\/strong\u003e is designed specifically for partial discharge detection.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eComprehensive Acoustic Inspection\u003c\/strong\u003e\u003cbr\u003eCombines \u003cstrong\u003epressurized leak, mechanical fault, and partial discharge detection\u003c\/strong\u003e in a single acoustic imaging camera.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eMechanical Fault Detection\u003c\/strong\u003e\u003cbr\u003eHelps identify bearing problems and other mechanical faults early, supporting preventative maintenance and reducing the risk of costly downtime.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIndustrial Gas \u0026amp; Compressed Air Leak Quantification\u003c\/strong\u003e\u003cbr\u003eMeasures leak rates and associated costs for industrial gases and compressed air, helping users prioritize repairs and calculate potential savings.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003ePartial Discharge Detection \u0026amp; Classification\u003c\/strong\u003e\u003cbr\u003eDetects PD issues and provides \u003cstrong\u003eseverity assessment and type classification\u003c\/strong\u003e both on the camera and through compatible software.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eNo Wi-Fi Configuration\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003eSi2-Pro-No-Wi-Fi\u003c\/strong\u003e is designed without Wi-Fi connectivity for facilities where wireless communication is restricted or unavailable.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eAutomatic Frequency Tuning\u003c\/strong\u003e\u003cbr\u003eAutomatically optimizes frequency settings to simplify acoustic inspections and improve detection efficiency.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e8x Digital Zoom\u003c\/strong\u003e\u003cbr\u003eProvides magnification for inspecting distant equipment and acoustic sources.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e12 MP Digital Camera\u003c\/strong\u003e\u003cbr\u003eCaptures detailed visual images to support inspection documentation and analysis.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eQR Code Reader\u003c\/strong\u003e\u003cbr\u003eProvides QR code scanning capabilities to support equipment identification and inspection workflows.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIP54 Protection\u003c\/strong\u003e\u003cbr\u003eProvides protection against dust ingress and water splashes for demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eMain Applications\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eRoutine Industrial Inspections\u003c\/strong\u003e\u003cbr\u003eSuitable for routine inspection and preventative maintenance across a range of industrial environments.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eBearing \u0026amp; Mechanical Fault Detection\u003c\/strong\u003e\u003cbr\u003eIdentify faulty bearings and other mechanical problems early to help plan repairs and avoid unexpected downtime.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eCompressed Air \u0026amp; Gas Leak Management\u003c\/strong\u003e\u003cbr\u003eDetect and quantify leaks, helping facilities reduce operating costs and prioritize repairs based on potential savings.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eElectrical Equipment Inspection\u003c\/strong\u003e\u003cbr\u003eDetect, classify, and assess partial discharge issues to support safer and more effective electrical equipment maintenance.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eSafety \u0026amp; Preventative Maintenance\u003c\/strong\u003e\u003cbr\u003eIdentify potential hazards and developing equipment problems before they result in costly failures or operational disruptions.\u003c\/p\u003e\n\u003ch3\u003eModel Comparison\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth align=\"center\"\u003ePressurized Leaks\u003c\/th\u003e\n\u003cth align=\"center\"\u003eMechanical Faults\u003c\/th\u003e\n\u003cth align=\"center\"\u003ePartial Discharge\u003c\/th\u003e\n\u003cth align=\"center\"\u003eHazardous Location\u003c\/th\u003e\n\u003cth align=\"center\"\u003eWi-Fi\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSi2-LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSi2x-LD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSi2-PD\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSi2-PRO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSi2x-PRO\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSi2-LD-No-Wi-Fi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSi2-PD-No-Wi-Fi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSi2-PRO-No-Wi-Fi\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e✔\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIn the Box\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Item\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcoustic Imaging Camera\u003c\/td\u003e\n\u003ctd\u003eSi2-Pro No-Wi-Fi version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Charger\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cable\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeck Strap\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHard Transport Case\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLIR Si-Series Plugin for FLIR Thermal Studio\u003c\/td\u003e\n\u003ctd\u003ePerpetual license\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Studio\u003c\/td\u003e\n\u003ctd\u003eSold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinted Documentation\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Memory Stick\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eFLIR Si2-Pro-No-Wi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAcoustic imaging camera\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Applications\u003c\/td\u003e\n\u003ctd\u003ePartial discharge, pressurized leak, and mechanical fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eNo Wi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Detection Distance\u003c\/td\u003e\n\u003ctd\u003e200 m (656 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressurized Leak Detection\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial Gas Leak Quantification\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Fault Detection\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePartial Discharge Detection\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePD Severity Assessment\u003c\/td\u003e\n\u003ctd\u003eOn-camera and software-based\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePD Type Classification\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Frequency Tuning\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Zoom\u003c\/td\u003e\n\u003ctd\u003e8x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Camera\u003c\/td\u003e\n\u003ctd\u003e12 MP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQR Code Reader\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Acoustic Frequency\u003c\/td\u003e\n\u003ctd\u003e51 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Acoustic Imaging Distance\u003c\/td\u003e\n\u003ctd\u003e656 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLIR Si2-Pro-No-Wi-Fi\u003c\/strong\u003e provides a comprehensive \u003cstrong\u003enon-Wi-Fi acoustic inspection solution\u003c\/strong\u003e for industrial applications, combining \u003cstrong\u003epartial discharge detection, gas and compressed air leak quantification, and mechanical fault detection\u003c\/strong\u003e. Its advanced analysis capabilities, automatic tuning, QR code reader, and field-ready design help maintenance teams \u003cstrong\u003eidentify problems early, prioritize repairs, reduce operating costs, and prevent unexpected equipment downtime\u003c\/strong\u003e\u003c\/p\u003e","brand":"Flir","offers":[{"title":"Default Title","offer_id":47175125237932,"sku":"T912636","price":27590.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0658\/2707\/8316\/files\/www.flir_0df3bed8-36e2-47e1-b8a9-2ecbb1d53d32.png?v=1789063262","url":"https:\/\/precisionperformances.com\/products\/flir-si2-pro-no-wi-fi-acoustic-imaging-camera-for-partial-discharge-pressurized-leak-and-mechanical-fault-detection-no-wifi","provider":"Precision Performances","version":"1.0","type":"link"}