{"product_id":"flir-mr176-kit5-imaging-moisture-meter-pro-kit-9hz","title":"FLIR MR176-Kit5 Imaging Moisture Meter Pro Kit, 9Hz","description":"\u003ch3\u003eFLIR MR176-KIT5 Imaging Moisture Meter Pro Kit, 9Hz\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLIR MR176-KIT5\u003c\/strong\u003e is a professional \u003cstrong\u003eimaging moisture meter pro kit\u003c\/strong\u003e designed to provide greater flexibility when locating, measuring, and diagnosing moisture problems in building and maintenance applications. Featuring \u003cstrong\u003eInfrared Guided Measurement (IGM™)\u003c\/strong\u003e technology, the MR176 helps users quickly identify areas of potential hidden moisture and determine where to take further measurements.\u003c\/p\u003e\n\u003cp\u003eThe MR176 combines a built-in \u003cstrong\u003eFLIR Lepton® thermal imaging sensor\u003c\/strong\u003e, an integrated \u003cstrong\u003epinless moisture sensor\u003c\/strong\u003e, and an external pin probe, allowing users to perform both \u003cstrong\u003enon-intrusive and intrusive measurements\u003c\/strong\u003e. The kit also includes the \u003cstrong\u003eMR08 Hammer and Wall Cavity Probe Combo\u003c\/strong\u003e for additional measurement applications.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003efield-replaceable temperature and relative humidity sensor\u003c\/strong\u003e helps minimize downtime by allowing the sensor to be replaced when needed. The MR176 also automatically calculates environmental readings including \u003cstrong\u003edew point, vapor pressure, and mixing ratio\u003c\/strong\u003e, providing additional information for evaluating moisture conditions.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eInfrared Guided Measurement (IGM™)\u003c\/strong\u003e\u003cbr\u003eUses thermal imaging to visually guide users toward areas where moisture may be present, helping identify the appropriate location for further testing.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e80 × 60 FLIR Lepton® thermal imaging\u003c\/strong\u003e\u003cbr\u003eProvides \u003cstrong\u003e4,800 thermal pixels\u003c\/strong\u003e for identifying temperature differences that may indicate hidden moisture.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIntegrated pinless moisture sensor\u003c\/strong\u003e\u003cbr\u003eEnables \u003cstrong\u003enon-destructive moisture measurements\u003c\/strong\u003e without penetrating the inspected surface.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eExternal pin probe\u003c\/strong\u003e\u003cbr\u003eProvides \u003cstrong\u003eintrusive contact measurements\u003c\/strong\u003e for direct moisture verification.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eMR08 Hammer and Wall Cavity Probe Combo\u003c\/strong\u003e\u003cbr\u003eProvides additional probing options for advanced moisture measurements, including measurements in \u003cstrong\u003ewall cavities and other difficult-to-access areas\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eField-replaceable temperature and RH sensor\u003c\/strong\u003e\u003cbr\u003eThe replaceable environmental sensor can be changed when necessary, helping reduce downtime and extend the meter's service life.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eAutomatic environmental calculations\u003c\/strong\u003e\u003cbr\u003eAutomatically calculates environmental measurements such as \u003cstrong\u003edew point, vapor pressure, and mixing ratio\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eMultiple integrated measurements\u003c\/strong\u003e\u003cbr\u003eProvides access to moisture, temperature, relative humidity, dew point, vapor pressure, and mixing ratio measurements.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eSelectable thermal palettes\u003c\/strong\u003e\u003cbr\u003eChoose from \u003cstrong\u003efour color palettes\u003c\/strong\u003e to display thermal information according to inspection preferences.\u003c\/p\u003e\n\u003ch3\u003eThermal Imaging Features\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eFLIR MR176\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImaging Detector\u003c\/td\u003e\n\u003ctd\u003eFLIR Lepton® microbolometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Image Resolution\u003c\/td\u003e\n\u003ctd\u003e80 × 60 pixels \/ 4,800 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Frequency\u003c\/td\u003e\n\u003ctd\u003e9 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e51° × 38°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Response\u003c\/td\u003e\n\u003ctd\u003e8–14 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;150 mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Focus Distance\u003c\/td\u003e\n\u003ctd\u003e10 cm (4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic with manual lock scale option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser\u003c\/td\u003e\n\u003ctd\u003eSingle laser pointer centered on thermal image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2.3\" QVGA (320 × 240) color TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Palettes\u003c\/td\u003e\n\u003ctd\u003eIron, Rainbow, Ice, Greyscale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMoisture Measurement\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin Moisture Groups\u003c\/td\u003e\n\u003ctd\u003e9 material groups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin Moisture Range\u003c\/td\u003e\n\u003ctd\u003e7–30% MC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin Moisture Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% MC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin Moisture Range Above 30%\u003c\/td\u003e\n\u003ctd\u003e30–100%, reference only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePinless Moisture Range\u003c\/td\u003e\n\u003ctd\u003e0–100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pinless Depth\u003c\/td\u003e\n\u003ctd\u003e0.75\" (19 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin Response Time\u003c\/td\u003e\n\u003ctd\u003e750 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePinless Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eThermo-Hygrometer Measurements\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eBasic Accuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Temperature\u003c\/td\u003e\n\u003ctd\u003e0–50°C (32–122°F)\u003c\/td\u003e\n\u003ctd\u003e±0.6°C (±1.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–100% RH\u003c\/td\u003e\n\u003ctd\u003e±2.5% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDew Point\u003c\/td\u003e\n\u003ctd\u003e-30–50°C (-22–122°F)\u003c\/td\u003e\n\u003ctd\u003e±1.0°C (±1.8°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMixing Ratio\u003c\/td\u003e\n\u003ctd\u003e0–560 GPP \/ 0–80.0 g\/kg\u003c\/td\u003e\n\u003ctd\u003e±2 GPP \/ ±0.25 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVapor Pressure\u003c\/td\u003e\n\u003ctd\u003e0–12.0 kPa\u003c\/td\u003e\n\u003ctd\u003e±0.05 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProbe \u0026amp; Measurement Accessories\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eMR176-KIT5\u003c\/strong\u003e includes the \u003cstrong\u003eMR08 Hammer and Wall Cavity Probe Combo\u003c\/strong\u003e, expanding the meter's measurement capabilities for different building materials and inspection situations.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eStandard pin probe\u003c\/strong\u003e — for direct intrusive moisture measurement.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003ePinless sensor\u003c\/strong\u003e — for non-destructive moisture detection.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eHammer probe\u003c\/strong\u003e — provides an additional measurement method for applicable materials.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWall cavity probe\u003c\/strong\u003e — allows measurements in wall cavities and other difficult-to-access locations.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eMR01 temperature\/RH sensor\u003c\/strong\u003e — field-replaceable sensor for environmental measurements.\u003c\/p\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Moisture Analysis\u003c\/h3\u003e\n\u003cp\u003eThe MR176-KIT5 provides more than basic moisture measurement by combining moisture readings with environmental conditions.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eTemperature measurement\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003eRelative humidity measurement\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003eDew point calculation\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003eVapor pressure measurement\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003eMixing ratio calculation\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003ePin moisture measurement\u003c\/strong\u003e\u003cbr\u003e• \u003cstrong\u003ePinless moisture measurement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese measurements can help users evaluate whether environmental conditions may contribute to \u003cstrong\u003econdensation, moisture accumulation, or building material moisture problems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eDisplay \u0026amp; User Interface\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eQVGA color TFT graphical display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e2.3 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e320 × 240 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Palettes\u003c\/td\u003e\n\u003ctd\u003eIron, Rainbow, Ice, Greyscale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Orientation\u003c\/td\u003e\n\u003ctd\u003eCenter of thermal image\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMenu System\u003c\/td\u003e\n\u003ctd\u003eEasy-to-navigate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eImage \u0026amp; Data Storage\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaved Image Format\u003c\/td\u003e\n\u003ctd\u003eBMP with measurement values overlaid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStored Image Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 9,999 images\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic with manual lock scale option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Display\u003c\/td\u003e\n\u003ctd\u003eColor thermal\/moisture information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReporting\u003c\/td\u003e\n\u003ctd\u003eCompatible with FLIR Tools software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.7 V, 3000 mAh Li-ion rechargeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging\u003c\/td\u003e\n\u003ctd\u003eMicro USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Runtime\u003c\/td\u003e\n\u003ctd\u003eUp to 18 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Usage\u003c\/td\u003e\n\u003ctd\u003eUp to 4 work weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIncluded Accessories\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIncluded Item\u003c\/th\u003e\n\u003cth\u003ePurpose\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFLIR MR176\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImaging moisture meter with IGM™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMR08 Hammer Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdditional moisture measurement applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMR08 Wall Cavity Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMoisture measurement in wall cavities\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField-Replaceable Temperature\/RH Sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnvironmental temperature and humidity measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Pin Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntrusive\/contact moisture measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Charger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCharging\/connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eQuick Start Guide\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProduct setup and operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Size\u003c\/td\u003e\n\u003ctd\u003e33 × 14 × 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackaging Size (inches)\u003c\/td\u003e\n\u003ctd\u003e13 × 5.5 × 4.75 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCE, FCC Class B, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Standard\u003c\/td\u003e\n\u003ctd\u003eEN 60825-1 Class 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eImaging Moisture Meter Pro Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFLIR MR176-KIT5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eInfrared Guided Measurement (IGM™)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Detector\u003c\/td\u003e\n\u003ctd\u003eFLIR Lepton® microbolometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Resolution\u003c\/td\u003e\n\u003ctd\u003e80 × 60 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Frequency\u003c\/td\u003e\n\u003ctd\u003e9 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of View\u003c\/td\u003e\n\u003ctd\u003e51° × 38°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;150 mK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Focus Distance\u003c\/td\u003e\n\u003ctd\u003e10 cm \/ 4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin Moisture Groups\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePin Moisture Range\u003c\/td\u003e\n\u003ctd\u003e7–30% MC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePinless Moisture Range\u003c\/td\u003e\n\u003ctd\u003e0–100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePinless Measurement Depth\u003c\/td\u003e\n\u003ctd\u003e19 mm \/ 0.75\" max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Temperature\u003c\/td\u003e\n\u003ctd\u003e0–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0–100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDew Point\u003c\/td\u003e\n\u003ctd\u003e-30–50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVapor Pressure\u003c\/td\u003e\n\u003ctd\u003e0–12.0 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMixing Ratio\u003c\/td\u003e\n\u003ctd\u003e0–560 GPP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2.3\" QVGA color TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaser Pointer\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Storage\u003c\/td\u003e\n\u003ctd\u003eUp to 9,999 images\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3.7 V, 3000 mAh Li-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Runtime\u003c\/td\u003e\n\u003ctd\u003eUp to 18 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging\u003c\/td\u003e\n\u003ctd\u003eMicro USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-Replaceable Temperature\/RH Sensor\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHammer Probe\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWall Cavity Probe\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFLIR Tools Compatibility\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLIR MR176-KIT5\u003c\/strong\u003e provides a comprehensive solution for \u003cstrong\u003eadvanced moisture inspection and building diagnostics\u003c\/strong\u003e, combining \u003cstrong\u003eIGM™ thermal guidance, pin and pinless moisture measurement, thermo-hygrometer functions, and specialized hammer and wall cavity probes\u003c\/strong\u003e. Its field-replaceable environmental sensor and multiple measurement options help users \u003cstrong\u003ereduce downtime, investigate moisture more efficiently, and obtain a more complete understanding of building moisture conditions\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Precision Performances","offers":[{"title":"Default Title","offer_id":47218741969068,"sku":"MR176-KIT5","price":1899.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0658\/2707\/8316\/files\/www.flir_ffcb206b-c2f0-4599-afb2-08338a61a2ac.png?v=1789512007","url":"https:\/\/precisionperformances.com\/products\/flir-mr176-kit5-imaging-moisture-meter-pro-kit-9hz","provider":"Precision Performances","version":"1.0","type":"link"}