{"product_id":"flir-gf77-gas-find-ir-with-25-lr-25-hr-and-6-hr-lenses-85206-0102","title":"FLIR GF77 - Gas Find IR with 25° LR, 25° HR and 6° HR Lenses (85206-0102)","description":"\u003ch3\u003eFLIR GF77 Gas Find IR – 25° LR, 25° HR \u0026amp; 6° HR Lenses (85206-0102)\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLIR GF77\u003c\/strong\u003e is a professional \u003cstrong\u003eoptical gas imaging camera\u003c\/strong\u003e designed to safely locate gas leaks while also providing \u003cstrong\u003eradiometric temperature measurement\u003c\/strong\u003e for thermal inspections. Its uncooled microbolometer detector and interchangeable lens system provide the flexibility needed to detect a wide range of gas emissions, making it suitable for \u003cstrong\u003eelectric power utilities, oil and natural gas operations, chemical and manufacturing facilities, food and agriculture applications, and first responders\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration includes \u003cstrong\u003ethree interchangeable lenses: 25° LR, 25° HR, and 6° HR\u003c\/strong\u003e. The \u003cstrong\u003e25° LR lens\u003c\/strong\u003e provides broader gas detection coverage for \u003cstrong\u003emethane, nitrous oxide, propane, sulfur dioxide, R-134a, and R-152a\u003c\/strong\u003e, while the \u003cstrong\u003e25° HR and 6° HR lenses\u003c\/strong\u003e provide high-resolution detection of \u003cstrong\u003esulfur hexafluoride (SF6), ethylene, ammonia, and R-12\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe GF77 combines gas detection and thermal inspection capabilities in one camera. Its \u003cstrong\u003e320 × 240 infrared resolution\u003c\/strong\u003e, built-in thermographic calibration, and advanced image-enhancement features help users identify gas emissions and thermal anomalies efficiently. \u003cstrong\u003eFLIR 1-Touch Level\/Span\u003c\/strong\u003e automatically enhances image contrast, while \u003cstrong\u003eFLIR High Sensitivity Mode (HSM)\u003c\/strong\u003e helps accentuate gas plume movement.\u003c\/p\u003e\n\u003cp\u003eAdditional features include \u003cstrong\u003elaser-assisted autofocus, GPS, Wi-Fi, image annotation, and rapid reporting capabilities\u003c\/strong\u003e, making it easier to organize findings and document inspections in the field. The purchase of a GF77 camera includes a \u003cstrong\u003e3-month subscription to FLIR Thermal Studio Pro and FLIR Route Creator\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eOptical Gas Imaging\u003c\/strong\u003e\u003cbr\u003eProvides safe, non-contact visualization of gas emissions to help identify and locate leaks.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eThree Interchangeable Lenses Included\u003c\/strong\u003e\u003cbr\u003eIncludes \u003cstrong\u003e25° LR, 25° HR, and 6° HR lenses\u003c\/strong\u003e, providing flexibility for different inspection distances, fields of view, and gas detection requirements.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWide Range of Detectable Gases\u003c\/strong\u003e\u003cbr\u003eThe LR lens detects \u003cstrong\u003emethane, nitrous oxide, propane, sulfur dioxide, R-134a, and R-152a\u003c\/strong\u003e, while the HR lenses detect \u003cstrong\u003eSF6, ethylene, ammonia, and R-12\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eRadiometric Thermal Measurement\u003c\/strong\u003e\u003cbr\u003eBuilt-in thermographic calibration allows the GF77 to perform \u003cstrong\u003eradiometric temperature measurements\u003c\/strong\u003e in addition to gas detection.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eFLIR 1-Touch Level\/Span\u003c\/strong\u003e\u003cbr\u003eAutomatically adjusts image contrast to make gas clouds and thermal differences easier to visualize.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eFLIR High Sensitivity Mode (HSM)\u003c\/strong\u003e\u003cbr\u003eEnhances plume movement to help users identify and track gas emissions.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eLaser-Assisted Autofocus\u003c\/strong\u003e\u003cbr\u003eHelps users quickly obtain accurate focus during inspections.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e320 × 240 Infrared Resolution\u003c\/strong\u003e\u003cbr\u003eProvides \u003cstrong\u003e76,800 infrared pixels\u003c\/strong\u003e for detailed thermal and gas imaging.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e5 MP Visual Camera\u003c\/strong\u003e\u003cbr\u003eIncludes a visible-light camera with an integrated LED light for documenting inspection areas.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eAdvanced Field Documentation\u003c\/strong\u003e\u003cbr\u003eGPS, Wi-Fi, annotation, and reporting capabilities help users organize findings and create inspection reports efficiently.\u003c\/p\u003e\n\u003ch3\u003eImaging \u0026amp; Optical\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIR Resolution\u003c\/td\u003e\n\u003ctd\u003e320 × 240 pixels (76,800 pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eUncooled microbolometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Pitch\u003c\/td\u003e\n\u003ctd\u003e25 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Lenses\u003c\/td\u003e\n\u003ctd\u003e25° LR, 25° HR, 6° HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Lenses\u003c\/td\u003e\n\u003ctd\u003e25° HR, 25° LR, 6° HR, 6° LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLens Calibration\u003c\/td\u003e\n\u003ctd\u003eService calibration required when changing lenses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25° Lens FOV\u003c\/td\u003e\n\u003ctd\u003e25° × 19°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6° Lens FOV\u003c\/td\u003e\n\u003ctd\u003e6.4° × 4.9°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25° Lens Focal Length\u003c\/td\u003e\n\u003ctd\u003e18 mm (0.71 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6° Lens Focal Length\u003c\/td\u003e\n\u003ctd\u003e74 mm (2.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25° Lens f-number\u003c\/td\u003e\n\u003ctd\u003e1.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6° Lens f-number\u003c\/td\u003e\n\u003ctd\u003e1.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Zoom\u003c\/td\u003e\n\u003ctd\u003e1–6× continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Rate\u003c\/td\u003e\n\u003ctd\u003e30 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage Frequency\u003c\/td\u003e\n\u003ctd\u003e30 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25° Lens Minimum Focus Distance\u003c\/td\u003e\n\u003ctd\u003e0.3 m (0.98 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6° Lens Minimum Focus Distance\u003c\/td\u003e\n\u003ctd\u003e5 m (16.4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25° Lens Minimum Focus Distance with MSX\u003c\/td\u003e\n\u003ctd\u003e0.65 m (2.1 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25° Lens Spatial Resolution (IFOV)\u003c\/td\u003e\n\u003ctd\u003e1.4 mrad\/pixel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6° Lens Spatial Resolution (IFOV)\u003c\/td\u003e\n\u003ctd\u003e0.36 mrad\/pixel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25° Lens Thermal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;25 mK at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6° Lens Thermal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;40 mK at 30°C (86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR Spectral Range\u003c\/td\u003e\n\u003ctd\u003e7–8.5 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHR Spectral Range\u003c\/td\u003e\n\u003ctd\u003e9.5–12 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Camera\u003c\/td\u003e\n\u003ctd\u003e5 MP with LED light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e4\" 640 × 480 touchscreen LCD with auto-rotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Radiometric IR Video\u003c\/td\u003e\n\u003ctd\u003eH.264 to memory card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Radiometric IR Video Streaming\u003c\/td\u003e\n\u003ctd\u003eH.264\/MPEG-4 over RTSP via Wi-Fi; MJPEG over UVC or Wi-Fi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiometric IR Video Recording\u003c\/td\u003e\n\u003ctd\u003eReal-time radiometric recording (.csq)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiometric IR Video Streaming\u003c\/td\u003e\n\u003ctd\u003eCompressed over UVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Video Recording\u003c\/td\u003e\n\u003ctd\u003eH.264 to memory card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGas Detection\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR Gas Detection\u003c\/td\u003e\n\u003ctd\u003eMethane, nitrous oxide, propane, sulfur dioxide, R-134a, R-152a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHR Gas Detection\u003c\/td\u003e\n\u003ctd\u003eSulfur hexafluoride (SF6), ethylene, ammonia, R-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR CH₄ Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR N₂O Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;75 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR C₃H₈ Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;400 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR SO₂ Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;30 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR R-134a Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLR R-152a Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHR SF6 Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHR C₂H₄ Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHR NH₃ Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;20 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHR R-12 Sensitivity\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;4 ppm × m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Conditions\u003c\/td\u003e\n\u003ctd\u003eΔT = 10°C; Distance = 1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMeasurement \u0026amp; Analysis\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤100°C: ±3°C (±5.4°F); \u0026gt;100°C: ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Conditions\u003c\/td\u003e\n\u003ctd\u003eAmbient temperature 15–35°C (59–95°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range 1\u003c\/td\u003e\n\u003ctd\u003e-20 to 80°C (-4 to 176°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range 2\u003c\/td\u003e\n\u003ctd\u003e0 to 250°C (32 to 482°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range 3\u003c\/td\u003e\n\u003ctd\u003e100 to 500°C (32 to 932°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eRadiometric temperature measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Detection\u003c\/td\u003e\n\u003ctd\u003eOptical gas imaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication \u0026amp; Data Storage\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImage File Format\u003c\/td\u003e\n\u003ctd\u003eStandard JPEG with measurement data included; infrared-only mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0, Bluetooth®, Wi-Fi, DisplayPort\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Media\u003c\/td\u003e\n\u003ctd\u003eRemovable SD card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVideo Storage\u003c\/td\u003e\n\u003ctd\u003eH.264 to memory card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Subscription\u003c\/td\u003e\n\u003ctd\u003e3-month FLIR Thermal Studio Pro and FLIR Route Creator subscription included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003eRechargeable Li-ion battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\u003ctd\u003e3.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Operating Time\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;4 hours at 25°C (68°F) under typical use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating \/ Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e-15 to 50°C (5 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70°C (-40 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEncapsulation\u003c\/td\u003e\n\u003ctd\u003eIP54 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eEN\/UL\/CSA\/PSE 60950-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock\u003c\/td\u003e\n\u003ctd\u003e25 g (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e2 g (IEC 60068-2-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eUNC ¼\"-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eFLIR GF77 Gas Find IR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e85206-0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Lenses\u003c\/td\u003e\n\u003ctd\u003e25° LR, 25° HR, 6° HR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions – Lens Vertical\u003c\/td\u003e\n\u003ctd\u003e150.5 × 201.3 × 84.1 mm (5.9 × 7.9 × 3.3 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions – Lens Horizontal\u003c\/td\u003e\n\u003ctd\u003e150.5 × 201.3 × 167.3 mm (5.9 × 7.9 × 6.6 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight – GF77 25° (1)\u003c\/td\u003e\n\u003ctd\u003e1.54 kg (3.4 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight – GF77 25° (2)\u003c\/td\u003e\n\u003ctd\u003e1.68 kg (3.7 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight – 25° (1) + 6° (1)\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (4.2 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight – 25° (2) + 6° (1)\u003c\/td\u003e\n\u003ctd\u003e2.05 kg (4.51 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLIR GF77 Gas Find IR with 25° LR, 25° HR, and 6° HR Lenses\u003c\/strong\u003e offers a versatile solution for \u003cstrong\u003egas leak detection and radiometric thermal inspection\u003c\/strong\u003e. With three included lenses spanning LR and HR spectral ranges, the system provides broad inspection flexibility and detection of multiple gas types. Combined with \u003cstrong\u003eadvanced gas visualization, interchangeable optics, thermal measurement, and field documentation tools\u003c\/strong\u003e, the GF77 is well suited for utility, industrial, manufacturing, energy, and environmental inspection applications.\u003c\/p\u003e","brand":"Precision Performances","offers":[{"title":"Default Title","offer_id":47158106620076,"sku":"85206-0102","price":51500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0658\/2707\/8316\/files\/www.flir_c69a2a22-c9ac-4b47-b885-46227adbd20f.png?v=1788891040","url":"https:\/\/precisionperformances.com\/products\/flir-gf77-gas-find-ir-with-25-lr-25-hr-and-6-hr-lenses-85206-0102","provider":"Precision Performances","version":"1.0","type":"link"}