{"product_id":"flir-cm85-2-trms-power-clamp-meter-with-wireless-meterlink-1000-a","title":"FLIR CM85-2 - TRMS Power Clamp Meter with Wireless METERLINK (1000 A)","description":"\u003ch3\u003eFLIR CM85-2 TRMS Power Clamp Meter with Wireless METERLiNK® – 1000 A\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLIR CM85-2\u003c\/strong\u003e is a professional \u003cstrong\u003eTrue RMS (TRMS) power clamp meter\u003c\/strong\u003e designed for industrial electrical troubleshooting, equipment testing, and advanced power analysis. With measurement capabilities up to \u003cstrong\u003e1,000 A AC\/DC\u003c\/strong\u003e and a \u003cstrong\u003e45 mm (1.77 in) jaw opening\u003c\/strong\u003e, the CM85-2 is designed to handle demanding electrical applications involving complex machinery and equipment.\u003c\/p\u003e\n\u003cp\u003eThe CM85-2 provides advanced measurement functions including \u003cstrong\u003eharmonics analysis, inrush current, power factor, peak hold, frequency, watts, and phase-related troubleshooting\u003c\/strong\u003e, while its dedicated \u003cstrong\u003eVariable Frequency Drive (VFD) mode\u003c\/strong\u003e helps improve measurement accuracy when working with VFD-controlled equipment.\u003c\/p\u003e\n\u003cp\u003eWith \u003cstrong\u003eTrue RMS AC current measurement\u003c\/strong\u003e, users can perform multiple-conductor measurements while maintaining reliable readings. The meter also features dual LED worklights and an ergonomic industrial design for convenient field operation.\u003c\/p\u003e\n\u003cp\u003eBuilt-in \u003cstrong\u003eBluetooth® connectivity\u003c\/strong\u003e allows the CM85-2 to stream live readings to a mobile device from up to \u003cstrong\u003e10 m (32 ft)\u003c\/strong\u003e away. Through the \u003cstrong\u003eFLIR METERLiNK® app\u003c\/strong\u003e, users can record measurements, compare log files, visualize trends, configure alarm thresholds, create reports, and share results with team members.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e• \u003cstrong\u003eAdvanced power analysis\u003c\/strong\u003e\u003cbr\u003eMeasures voltage, current, watts, power factor, frequency, harmonics, and other electrical parameters for comprehensive equipment troubleshooting.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eTrue RMS measurements\u003c\/strong\u003e\u003cbr\u003eProvides True RMS AC current measurement for accurate readings across complex electrical loads.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003e1000 A AC\/DC current measurement\u003c\/strong\u003e\u003cbr\u003eMeasures AC and DC current up to \u003cstrong\u003e999.9 A\u003c\/strong\u003e, with dedicated ranges for detailed electrical measurements.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eVariable Frequency Drive (VFD) mode\u003c\/strong\u003e\u003cbr\u003eImproves measurement accuracy when testing equipment controlled by variable frequency drives.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eHarmonics analysis\u003c\/strong\u003e\u003cbr\u003eMeasures total harmonic distortion and individual harmonics from \u003cstrong\u003eH01 through H25\u003c\/strong\u003e, helping identify power-quality issues.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eInrush current measurement\u003c\/strong\u003e\u003cbr\u003eCaptures startup current to help troubleshoot motors, machinery, and other electrical equipment.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eWireless METERLiNK® connectivity\u003c\/strong\u003e\u003cbr\u003eStream live readings over Bluetooth® to the METERLiNK app for data recording, trend visualization, alarm configuration, reporting, and sharing.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eDual LED worklights\u003c\/strong\u003e\u003cbr\u003eBuilt-in worklights improve visibility in dark or poorly lit electrical work areas.\u003c\/p\u003e\n\u003cp\u003e• \u003cstrong\u003eIndustrial safety rating\u003c\/strong\u003e\u003cbr\u003eRated \u003cstrong\u003eCAT IV-600 V and CAT III-1000 V\u003c\/strong\u003e for professional electrical testing applications.\u003c\/p\u003e\n\u003ch3\u003eMeasurement \u0026amp; Analysis\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e45 mm (1.77 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current\u003c\/td\u003e\n\u003ctd\u003e99.99 A and 999.9 A; ±2.0% + 5 digits at 50–60 Hz; ±2.5% + 5 digits above 60–400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Current\u003c\/td\u003e\n\u003ctd\u003e99.99 A \/ ±2% + 0.5 A; 999.9 A \/ ±2% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Voltage\u003c\/td\u003e\n\u003ctd\u003e99.99 V and 999.9 V; ±1.0% + 5 digits at 50–500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Voltage\u003c\/td\u003e\n\u003ctd\u003e99.99 V and 999.9 V; ±0.7% + 2 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Response\u003c\/td\u003e\n\u003ctd\u003eTrue RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance\u003c\/td\u003e\n\u003ctd\u003e3.999 µF to 3.999 mF \/ ±1.9% + 8 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuity\u003c\/td\u003e\n\u003ctd\u003e999.9 Ω \/ ±1.0% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiode\u003c\/td\u003e\n\u003ctd\u003e0.40–0.80 V \/ ±0.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e20.00–99.99 Hz; 20.0–999.9 Hz; 0.020–9.999 kHz \/ ±0.5% + 3 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonics\u003c\/td\u003e\n\u003ctd\u003eTHD ACA\/ACV up to 99.9%; H01–H12 and H13–H25 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003eACA: 99.99 A \/ ±3% + 0.3 A; 999.9 A \/ ±3% + 5 digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Rate\u003c\/td\u003e\n\u003ctd\u003e3 times per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Hold\u003c\/td\u003e\n\u003ctd\u003eACV up to 1400 V; ACA up to 1400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e-1.00 to 0.00 to +1.00 \/ ±3° ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e999.9 Ω to 99.99 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFD AC Voltage\u003c\/td\u003e\n\u003ctd\u003e99.99 V and 999.9 V \/ ±1% + 5 digits at 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVFD AC Current\u003c\/td\u003e\n\u003ctd\u003e99.99 A and 999.9 A \/ ±2% + 5 digits at 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatts – DC\u003c\/td\u003e\n\u003ctd\u003eUp to 999.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWatts – AC\u003c\/td\u003e\n\u003ctd\u003eUp to 999.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording\u003c\/td\u003e\n\u003ctd\u003eData recording available through METERLiNK® app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication \u0026amp; Data Storage\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eBluetooth®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBluetooth® Range\u003c\/td\u003e\n\u003ctd\u003eUp to 10 m (32 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Recording\u003c\/td\u003e\n\u003ctd\u003eAvailable through METERLiNK® app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMETERLiNK® Functions\u003c\/td\u003e\n\u003ctd\u003eData logging, log comparison, trend visualization, alarm thresholds, reporting, and sharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePower\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e6 × 1.5 V AAA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003eApproximately 50 hours with alkaline batteries, with backlight, worklight, and Bluetooth® off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd\u003eApproximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGeneral Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions [L × W × H]\u003c\/td\u003e\n\u003ctd\u003e276 × 101 × 50 mm (10.87 × 3.98 × 1.97 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJaw Opening\u003c\/td\u003e\n\u003ctd\u003e45 mm (1.77 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.65 kg (1.43 lb) including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorklights\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrop Test\u003c\/td\u003e\n\u003ctd\u003e1.2 m (4 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock \u0026amp; Vibration\u003c\/td\u003e\n\u003ctd\u003eRandom vibration per MIL-PRF-28800F Class 2, 5–55 Hz, 3 g maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Certifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category\u003c\/td\u003e\n\u003ctd\u003eCAT IV-600 V, CAT III-1000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CE, FCC, IC, UKCA, CSAUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1:2010; IEC 61010-2-032:2012; IEC 61010-2-033:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd\u003e0–10°C (32–50°F), non-condensing; 10–30°C (50–86°F), ≤80% RH; 30–40°C (86–104°F), ≤75% RH; 40–50°C (104–122°F), ≤45% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (14°F to 122°F), 0–80% RH, without batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.2 × specified accuracy\/°C below 18°C or above 28°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eFCC 47 CFR Part 15 Subpart B; EN IEC 61326-1:2021; EN IEC 61326-2-2:2021; EN 301 489-1; EN 301 489-17; ETSI EN 300 328; EN 62479; EN 50663\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited Lifetime Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe \u003cstrong\u003eFLIR CM85-2\u003c\/strong\u003e combines \u003cstrong\u003eTrue RMS power measurement, advanced harmonics analysis, VFD mode, inrush current testing, power factor measurement, and wireless METERLiNK® connectivity\u003c\/strong\u003e in a rugged industrial clamp meter. It is well suited for \u003cstrong\u003eindustrial electrical troubleshooting, motor and machinery diagnostics, VFD-controlled equipment, power-quality analysis, and preventive maintenance\u003c\/strong\u003e, providing technicians with detailed measurements and convenient wireless data management in the field.\u003c\/p\u003e","brand":"Precision Performances","offers":[{"title":"Default Title","offer_id":47152765829292,"sku":"CM85-2","price":569.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0658\/2707\/8316\/files\/www.flir_e0ee4653-85e3-45bd-bf4e-26cb88ecccc6.png?v=1788825016","url":"https:\/\/precisionperformances.com\/products\/flir-cm85-2-trms-power-clamp-meter-with-wireless-meterlink-1000-a","provider":"Precision Performances","version":"1.0","type":"link"}